Power cord requirements
The library is shipped with a seven-foot (2.1 meter), 18 AWG,
3-conductor AC power cord for 120 volt use in the United States and
Canada. The power cord has a molded NEMA 5-15P male connector on
one end and a molded IEC type CEE-22 female connector on the other
end. The power cord is UL Listed and CSA Certified.
Other voltages and international use
If you are planning to use an input voltage other than 120 volts AC or if
you plan to use the library outside of the United States or Canada, you
must supply your own power cord.
Criteria for U.S. and Canadian 220 VAC power cord
S
It must have a molded NEMA 6-15P attachment plug on one end.
S
It must have a molded IEC type CEE-22 female connector on the
other end.
S
The cordage must be an SJT or SVT type, 3-conductor, 18 AWG
minimum.
S
The power cord must comply with local electrical code.
Criteria for international 220 VAC power cord
S
It must have an attachment plug of the proper type, rating, and safety
approval for the intended country.
S
It must have an IEC type CEE-22 female connector on one end.
S
The flexible cord must be of a HAR (harmonized) type H05VV-F-
three-conductor cord with a minimum conductor size of 0.03 square
inches (1.0 square millimeters).