Release Notes

Release Notes
Document 6-00016-32 Rev A
September 2007
4 Resolved Issues
2876 Logical serial number (12 character) causing configuration errors with
TSM application.
2911 IVT test does not run LTO move cartridge test in 4th IE.
2931 418156 Library should compare drive fiducial labels with actual sled type.
2938 Service login timeout is handled incorrectly at "service->verify->all-
>perform all tests" screen if the 'Accept' input is 'y' when the timeout
occurs.
2939 Remove fibre channel topology and data rate selection for LTO-1 FC
drives.
2974 S10K Tape alert flags are reported incorrectly in the S10K log and need a
mechanism to report tape alert log data back to SDLC.
3024 550364 If the IE cable between the IE and the LMC becomes disconnected and a
new teach is performed the teach fails with SAC 01, 40, A3.
3031 On large dual aisle systems, it has been observed that tower 13 sometimes
fails to teach new on the secondary aisle side.
3032 566896 Serial number and logical serial number are truncated by 1 character on
the operator panel.
3038 527016 E_LSC_WFSCRDBF_BAD_READBUFFER_HANDLE is reported with
RMU 192 and 304 Library firmware.
3041 622572 If a LTO barcode label is printed in the reverse direction the library
incorrectly places the label into the bottom cell and forces a rescan.
3045 Need to merge changes form CR64557(support of LB and LX media for
3592 drives) onto main tree for 320.
3050 582456 On systems with a lot of drives (70+ drives), the Log sense page 3B
interferes with vary on of drive causing SAC 71.
3071 Need to add changes (DDC\LDC\LBI boot \appl code problem 313 code)
to 320 code.
3073 3592 drive modules power supply diags for the 4th drive bay do not work
properly.
3074 S10K 314A FW does not identify media type and usage.
3075 3592 short media returns an incorrect media character through SCSI read
element status.
3081 Code can take the library offline and not post an error.
3352 When varying a drive offline the library does not queue a unit attention
until the menu is exited. It should queue the UA as soon as the drive has
been varied offline and not wait for the user to exit the menu.
Change
Request
Number
Service
Request
Number
Description