Operating instructions
Shutting Down the Scalar 10K 3-9
September 2007
Step 2 Locate the Main Power Switch at the lower right
corner of the CM.
Step 3 Set the Main Power Switch to off.
Power is removed from the CM.
Step 4 Repeat Step 2 and Step 3 for each Drive Module.
Emergency Shutdown
Use the following procedure if an emergency situation arises.
Except in emergencies, stop the Scalar 10K with the normal
shutdown procedure before switching off the Main Power
Switch. Quantum is not responsible for damage caused by
improper use of the Main Power Switch. All risk lies
entirely with the user.
With the RMU installed, power up must be delayed by one
minute after a power down condition to allow the RMU to
properly reset.
Step 1 Locate the Main Power Switch at the lower right
corner of the CM.
Step 2 Set the Main Power Switch to off.
Power is removed from the Scalar 10K CM. All Accessor
movement stops immediately and the gripper descends.
Step 3 Repeat Step 1 and Step 2 for each DM.
Warning
Caution