Operating instructions

Setup Menu 4-85
September 2007
Parameters Description
Auto Teach Y to enable Auto Teach for
automatic configuration and
calibration on each power
cycle.
N to disable Auto Teach on
each power cycle.
Auto Inventory Y to enable Auto Inventory for
automatic cartridge scanning
inventory on each power cycle.
N to disable Auto Inventory on
each power cycle.
Operating Mode 0 to select Normal mode of
operation. In this mode, the
library does not wait after a
drive is reported to be ejected,
and the library does not issue
and EJECT command (these
commands must be issued by
the host application).
1 to select a 3 second delay
before a Get operation is
performed on a drive after
detecting that a tape was
ejected.
2 to allow the Scalar 10K to
issue an UNLOAD command
to the drive if the cartridge is
not ejected by the host. This is
the default setting.
3 to activate options 1 and 2.
4 to disable automatic
cartridge recovery on PUT
failures.
5 to activate options 1 and 4.
6 to activate options 2 and 4.
7 to activate options 3 and 4.
Accept Y to accept changes.
N to reject changes.
If Y is selected, the screen updates to reflect the changes.
Otherwise, the changed parameters continue to display
but no action is taken.