Operating instructions

Setup Menu 4-67
September 2007
Target ID Dialog
Path: Main Menu Setup Library SCSI Target ID
Use the Target ID Dialog to set the library SCSI ID.
See Figure 4-92. Changes do not take effect until library power
is cycled.
Note: In Dual Aisle configurations, make sure that each aisle
(primary and secondary) has a unique SCSI ID.
Figure 4-92 Target ID Dialog
Parameters Description
Bus 1: Next Next indicates the SCSI ID
address that takes effect for
bus port 1 after power is cycled
(0–7)
Bus 1: Now Now the SCSI ID address that
is currently in effect (0–7) for
bus port 1
Bus 2: Next Next indicates the SCSI ID
address that takes effect for
bus port 2 after power is cycled
(0–7)
Bus 2: Now Now the SCSI ID address that
is currently in effect (0–7) for
bus port 2
Accept Y to accept changes
N to reject changes
If Y is selected, the screen updates to reflect the changes.
Otherwise, the changed parameters continue to display
but no action is taken.
Note
The Scalar 10K
defaults to SCSI
ID 6.
Target ID: NextNow
Bus 1:6< 6
Bus 2: 6 6
Accept: N