Operating instructions

4-58 Menus and Commands
6-00058-05 Rev A
Eject Clean Tape Dialog
Path: Main Menu Commands Insert/Eject Eject Clean
Tape
Use the Eject Clean Tape Dialog to remove a cleaning
cartridge without opening the service or access door, or
without host intervention. See Figure 4-76.
Figure 4-76 Eject Clean Tape Dialog
Parameters Description
Coord The first field indicates the
type of cell (I for I/E Station, D
for Drive, S for Storage cell)
The second field indicates the
rack number (01–16)
The third field indicates the
storage cell section (1–5)
The fourth field indicates the
column of the section (A–P)
The fifth field indicates the
row of the column (01–15)
Index The device address associated
with the selected coordinate
parameter:
DT = data transfer device
IE = insert/eject device
ST = storage device
Accept Y to accept
N to reject
If Y is selected, the Clean Media Eject Screen appears.
See Figure 4-77. Otherwise, the changed actions
continue to display but no action is taken.
Enter SOURCE
Coord: S 01 1< A 01
Index: ST 00001
Accept: N