Operating instructions
Status Menu 4-23
September 2007
Parameters Description
Coord The first field indicates the
type of cell (I for I/E Station, D
for Drive, S for Storage cell)
The second field indicates the
rack number (01–16)
The third field indicates the
storage cell section (1–5)
The fourth field indicates the
column of the section (A–P)
The fifth field indicates the row
of the column (01–15)
Index The device address associated
with the selected coordinate
parameter:
DT = data transfer device
IE = insert/eject device
ST = storage device
Accept Y to accept
N to reject
If Y is selected, the Response Dialog appears. See
Figure 4-21 on page 4-23. Otherwise, the changed
parameters continue to display but no action is taken.
Figure 4-21 Response Dialog
Parameters Description
Status Full indicates that a cartridge
is present in the element
Empty indicates that the
cartridge is not present in the
element
BC Indicates the barcode label as
found on the cartridge when
the Status indicates Full
Status: Full
BC : 010116
Source: 0000
Valid : Yes[more]