Scalar 1000 Library Planning Guide
Copyright Notice © 2002–2004 ADIC The information contained in this document is subject to change without notice. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of ADIC.
Contents 1 Introduction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Associated Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tape Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Insert/Eject Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 SAN Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Preparation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Packaging Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 Physical Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi Contents 6-01150-01 Rev A
Figures Figure 2-1 Control Module and Expansion Module . . . . . . . . . . . . . . . . . . . . . . . 2-4 Figure 2-2 Storage Networking Fibre Channel Attachment (Through an SNC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Figure 2-3 Direct SCSI Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 Figure 2-4 Network Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii Figures 6-01150-01 Rev A
Tables Table 2-1 Drives and Storage Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Table 3-1 Library Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Table 4-1 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Table 4-2 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Table 4-3 Electrical Specifications . . . . . . . . . . . . . . .
x Tables 6-01150-01 Rev A
1 Introduction Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Associated Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Introduction 6-01150-01 Rev A
1- Overview This chapter provides general information on this manual, including intended audience, organization, associated documents, and where to acquire technical assistance. The information in this chapter is organized as follows: • Intended Audience on page 1-3 • Organization on page 1-3 • Associated Documents on page 1-4 • ADIC Technical Assistance Center on page 1-4 Intended Audience This manual is for sales personnel and potential purchasers of the Scalar 10001 library.
Chapter 5 Site Preparation - Provides forms for planning space, physical, electrical, and environmental requirements. This information is required by the installation team. Associated Documents 6-00054-xx Scalar 1000 Operator Guide 6-00055-xx Scalar 1000 SCSI Reference Manual 6-01151-xx Scalar 1000 Maintenance Guide ADIC Technical Assistance Center If problems cannot be solved with the aid of this document or if recommended training is desired, contact the ADIC Technical Assistance Center (ATAC).
2 System Description General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Control Module (CM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Expansion Module (EM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 System Description 6-01150-01 Rev A
2- General Description The Scalar 1000 automates the storage, retrieval, and control of 3590, LTO, DLT, SDLT, and AIT tape cartridges. Tape cartridges are mounted and dismounted in tape drives using application software from the host without operator intervention. Note To accommodate IBM 3590 drives, you must add an Extension frame to a Control Module or an Expansion Module to increase module depth.
Modules The Scalar 1000 Library has the following modules: • Control Module (CM) on page 2-5 • Expansion Module (EM) on page 2-5 Door Lock, Handle, and Key Operator Panel Insert/Eject Station Expansion Module Control Module Figure 2-1 2-4 System Description Control Module and Expansion Module 6-01150-01 Rev A
Control Module (CM) The CM is a single module, standalone Scalar 1000 library. It contains an LCD Operator Panel, AC and DC power supplies, robot control electronics, and host interfaces. It can be attached to an EM to create an expanded Scalar 1000 library. See Figure 2-1 on page 2-4. The tape and drive bay capacity varies in the CM.
Internal Components The Scalar 1000 consists of the following internal components: • Tape Drives • Cartridge Storage • Cartridge Accessor • Tape Cartridges • Insert/Eject Station Tape Drives The Scalar 1000 supports the following tape drives: • 3490E • NCTP • 3590 • DLT (high profile and low profile) • SDLT • AIT-1 • AIT-2 • AIT-3 • LTO-1 • LTO-2 Cartridge Accessor The Cartridge Accessor identifies and moves cartridges between the storage cells, tape drives, and the I/E Station
• An X-Axis drive for moving the Cartridge Accessor the length of the rails in the CM and the EMs. • A Y-Axis drive for moving the Gripper Assembly vertically in the CM and the EMs. Tape Cartridges The Scalar 1000 automates the retrieval, storage, and control of 3590, DLT, SDLT, LTO, and AIT cartridges. Note Duplicate barcode labels (even with different media identifiers) are NOT supported. Two characters are used to identify the cartridge type.
Connectivity The Scalar 1000 offers several different connectivity options, allowing the library to support a wide range of backup topologies and applications. Flexible library connectivity delivers active support for loop and switched fabric Fibre Channel protocols, along with SCSI. SAN Connectivity The Scalar 1000 can be connected to a Fibre Channel Storage Area Network (SAN) via the Storage Networking Controller (SNC).
Figure 2-2 22 June 2004 Storage Networking Fibre Channel Attachment (Through an SNC) Connectivity 2-9
SCSI Connectivity The Scalar 1000 can be directly connected to one or two SCSI buses. Because each SCSI bus is independent, it can be Single Ended, High Voltage Differential, or Low Voltage Differential. Both ends of each bus must be terminated and a terminator is shipped with each SCSI adapter card ordered. The minimum configuration of a Scalar 1000 library requires one SCSI adapter and the SCSI type (Single Ended, High Voltage Differential or Low Voltage Differential).
Scalar DLC Option The Scalar 1000, through its optional Scalar Distributed Library Control (Scalar DLC) interface, provides the industry’s most advanced combination of management and diagnostics. The Scalar DLC software serves as a centralized library management tool that simplifies and automates the tracking and management of all system resources for optimal performance and maximum availability. The Scalar DLC attaches to the library SCSI bus.
Figure 2-4 Network Attachment Remote Management Unit The factory-installed Remote Management Unit (RMU) in each system uses a standard web browser for remote library access. The supported browsers are: • Microsoft Internet Explorer version 4.0 and above • Netscape Navigator version 4.
• Access the library Operator Panel • Access Scalar 1000 documentation • Retrieve library command and event logs The RMU supports Simple Network Management Protocol (SNMP) version 2.0 and acts as an SNMP-server. The RMU acquires Tape Alert 3.0 compatible information from the library over the serial interface port and sends that information to a SNMP manager. The RMU also detects a power loss and generates a SNMP trap for notification.
2-14 System Description 6-01150-01 Rev A
3 System Configurations Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 System Configurations 6-01150-01 Rev A
3- Overview This chapter describes the Scalar 1000 library component configurations. The Scalar 1000 can consist of one to four modules (a Control Module and up to three Expansion Modules). See Table 3-1 for module, tape drive, and tape cartridge configuration information. Note Service requires 48 in. (1219 mm) access.
Configurations This section contains figures that show the four possible Scalar 1000 component configurations. • Basic Library with No Expansion Modules, Figure 3-1 • Library with One Expansion Module, Figure 3-2 on page 3-5 • Library with Two Expansion Modules, Figure 3-3 on page 3-6 • Library with Three Expansion Modules, Figure 3-4 on page 3-7 60 in. 1524 mm 30 in. 762 mm Service 18 in. Access 48 in. 457 mm 1219 mm 30 in. 762 mm 12 in. 305 mm 138 in. 3505 mm 60 in.
90 in. 2280 mm 30 in. 30 in. 762 mm 762 mm 18 in. 457 mm 30 in. 762 mm 12 in. 305 mm 60 in. 1524 mm (3590) Fully Extended I/E Station Control Module Expansion Module 47 in. 1193.8 mm (SDLT/DLT, LTO, AIT) 138 in. 3505 mm (3590) 125 in. 3175 mm (SDLT/DLT, LTO, AIT) 30 in. 762 mm 30 in.
120 in. 3048 mm 30 in. 762 mm 30 in. 762 mm 30 in. 762 mm 18 in. 457 mm 30 in. 762 mm 12 in. 305 mm 138 in. 3505 mm 60 in. 1524 mm (3590) Fully Extended I/E Station Control Module Expansion Module Expansion Module 47 in. 1193.8 mm (3590) 125 in. 3175 mm (SDLT/DLT, LTO, AIT) (SDLT/DLT, LTO, AIT) 30 in. 762 mm 30 in.
150 in. 3810 mm 30 in. 762 mm 30 in. 762 mm 30 in. 762 mm 30 in. 762 mm 18 in. 457 mm 30 in. 762 mm 12 in. 305 mm 60 in. 1524 mm (3590) Fully Extended I/E Station Control Module Expansion Module Expansion Module Expansion Module 47 in. 1193.8 mm (SDLT/DLT, LTO, AIT) 138 in. 3505 mm (3590) 125 in. 3175 mm (SDLT/DLT, LTO, AIT) 30 in. 762 mm 30 in.
3-8 System Configurations 6-01150-01 Rev A
4 System Specifications Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 System Specifications 6-01150-01 Rev A
4- Overview This chapter contains performance, environmental, electrical, and physical specification information for the Scalar 1000 library.
Electrical Specifications The electrical specifications for the Control Module (CM) and Expansion Module (EM) are shown in Table 4-3. Table 4-3 Electrical Specifications Module Voltage a (Single Phase) kVA United States Power Connector International Power Connector CM/EM 115 - 230 1.6 L5 - 20 Plug is customer supplied a. Connect an 18 gauge stranded copper wire from the CM to earth ground. The typical power consumption for a full-height/half-height drive and the SNC 5100 is shown in Table 4-4.
Physical Specifications The physical specifications for the library modules are shown in Table 4-5. The floor must support point loads exerted by the leveling pads of up to 86.42 lb./in2. In addition to being dust-free, physically, chemically, and acoustically appropriate, the flooring must meet the insulation resistance specifications. The insulation resistance between the floor surface and earth ground must be 1x105 to 1x108 ohms to prevent system failure or electrical shock.
Foot Pad Positions The Scalar 1000 foot pad positions are shown in Figure 4-1. The foot pad positions are the same for the CM and EM. 29.65 in. (753.2 mm) 46.71 in. (1186.4 mm) 2X 41.09 in. (1043.8 mm) 4X 2.00 in. (50.8 mm) 2X 2.81 in. (71.3 mm) 2X 1.84 in. (46.7 mm) 25.98 in. (659.
Barcode Requirements For customers who want to print barcode labels, the labels must meet the ANSI MH10.8M-1983 standard and other additional requirements. The following list outlines the ANSI MH10.8M-1983 standard and additional requirements: • ANSI MH10.
4-8 System Specifications 6-01150-01 Rev A
5 Site Preparation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Packaging Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 Physical Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Site Preparation 6-01150-01 Rev A
5- Overview This section solicits pertinent information about the delivery site. Record all requested general information. Packaging Dimensions The Scalar 1000 module packaging sizes are as follows: • Control Module (CM) packing size: 65 in. L (1651 mm) x 35 in. W (889 mm) x 78 in. H (1981 mm) and mounted on 150 lb. palettes. • Expansion Module (EM) packing size: 65 in. L (1651 mm) x 35 in. W (889 mm) x 78 in. H (1981 mm) and mounted on 150 lb. palettes.
General Information Note Customer Name: Place any additional information in Additional Comments on page 5-9.
Target Operational Date: Physical Environment Place any additional information in Additional Comments on page 5-9. Room Dimension: Ceiling Projection Floor Type Floor Load Capacity Fire Protection Access Conditions Access to Scalar 1000 library room (elevator, stairs, door widths, etc.
Dimensions and Location of Smallest Door or Opening: Loading Dock Specifications (dock height, type of ramps, weather protection, etc.
Semitrailer Accessibility (Y or N): ________ Preferred/Required Local Carrier Company: Where Can Trailer Be Left for Staging? Availability of Material Handling Equipment: Location for uncrating: Preferred Time of Day for Unloading and Moving Materials: 22 June 2004 Physical Environment 5-7
Off Hours/Weekends Accessibility for Installation Team: Procedure for Obtaining Building Passes: Procedure for Scheduling the Elevator, Loading Dock, etc.
Other Considerations: Additional Comments Record any additional information from other pages. For reference purposes, note the page number with the information. Add and number additional sheets as necessary.
5-10 Site Preparation 6-01150-01 Rev A
Index -AAccess Conditions . . . . . . . . . . . . . . . . . . . . . . . 5-5 Additional Comments . . . . . . . . . . . . . . . . . . . . 5-9 Assistance with Problems . . . . . . . . . . . . . . . . . 1-4 Associated Documents . . . . . . . . . . . . . . . . . . . 1-4 ATAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 -BBarcode Requirement . . . . . . . . . . . . . . . . . . . . 4-7 Insert/Eject Station . . . . . . . . . . . . . . . . . . . . . . .2-7 Intended Audience . . . . . .
in-2 Index 6-01150-01 Rev A