The
RDX
8000 unit supports a number of interactive diagnostic tests designed to check specific areas of operation of
the
device. The tests are all designed to be executed locally so the unit’s behavior can be observed. The tests are as
follows:
Slot UI Test:
It tests each slot for eject button indication and sensing- requires a local operator to interact with the
unit.
Display Test:
It tests the
LCD
display and backlight operation- requires a local operator to step the display with the
OCP
navigation
button and observe the display through various states to confirm
operation.
Fan Test:
It tests the operation of the
RDX
8000 cooling fan, steps the fan speed through four
RPM
ranges while monitoring fan
rpm.
Cartridge Access Test:
It tests the operation of each slot location by checking communication with a test cartridge. Execution of this
test
Will force the unit offline and eject all inserted cartridges from the unit. This is a data safety feature to insure the
test
operator can use a scratch cartridge. This test requires a local operator to interact with the
unit.
To start the diagnostic test sequence select each test by checking each test from the list that you would like to
perform
and push the “Start Diagnosticbutton.
Y
ou
may select to run only one test or all four, upon completion of
the selected test(s) a new diagnostic log status page will be created capturing the current test status.