User's Guide
18
RDX 8000
4.5 Powering up and powering down the
unit
The
RDX
8000 power button indicator will be solid amber when
AC
power is present at the unit indicating the unit is
in
Standby mode.
Press
and release the power button on the front panel to power up the
RDX
8000. During the power up process
the
power button indicator will change from solid amber to flashing green indicating the unit is in the process of
becoming ready. The
RDX
8000 unit will take approximately 3.5 minutes to complete the power up boot
sequence.
During
power
up a progress bar will be displayed in the
OCP
after approximately 90 seconds providing boot
progress indication
for
the
remaining start up sequence
oper
ations.
NOTICE
The
RDX
8000 will always start from standby mode if the last power shutdown of
the
unit
was performed via a normal shutdown to standby mode (shutdown
initiated by
the
pressing the power
but
ton).
If the unit was stopped or rebooted
because
of an
AC
power
interruption
the unit
will
automatically boot backup to
operation mode without the necessity of a power
button
push. This allows the
RDX
8000 to recover from power
errors without
additional
operator
intervention.
After
successful
completion of the power up
sequence,
the network interface will be available if an active
network
connection was detected. The
RDX
8000
OCP
(Operator Control
Panel)
will also become active and will display the
RD
X
8000 unit’s IP address for port 1.
Please
take note of this IP address which will be used to
access
the
RDX
8000
and
for
the
iSCSI
communication.
To power down the unit press and hold the power button for 4 seconds and release. The power indicator will flash
amber indicating the unit is in the process of powering down. Once the unit has completed the power
shutdown
sequence the power indicator will be solid amber indicating the unit is in Standby Mode.
NOTICE
Do not insert
RDX
cartridges until the preliminary
RDX
8000 configuration
process is
completed!
Figure 6 — Power up/down the
unit