User's Manual
Chapter 1 Installing StorNext File System and Storage Manager
Getting Ready to Install
StorNext 3.1.3 Installation Guide 6
of the operating system running on the MDC as well as the operating 
system running on all connected clients. Disk LUNs can have one of three 
labels: VTOC, EFI, or sVTOC (short VTOC).
Required disk LUN label settings based on operating system and LUN 
size are presented in 
Table 3. Before installing StorNext, decide what 
label type will be used, and then install any required operating system 
patches or updates (for both MDC and client) as indicated in the notes for 
Table 3.
Table 3 Required Disk LUN 
Labels
Note: After labeling a disk LUN, you must reboot systems running 
Solaris before they can access the disk LUN.
Operating 
System
Label for 
LUNs < 1 TB
Label for 
LUNs 1–2 TB
Label for 
LUNs > 2 TB
Windows XP
a
VTOC, EFI VTOC, EFI EFI, sVTOC
Windows 2003 
Server
VTOC, EFI VTOC, EFI EFI, sVTOC
Linux 2.6 
Kernel
VTOC, EFI VTOC, EFI EFI, sVTOC
Linux 2.4 
Kernel
VTOC, EFI VTOC, EFI Not supported
Solaris 9
b
VTOC, EFI EFI Not supported
Solaris 10
c
VTOC, EFI EFI EFI
HP-UX
a
VTOC, EFI VTOC, EFI EFI, sVTOC
IBM AIX
d
VTOC, EFI VTOC, EFI EFI, sVTOC
SGI IRIX VTOC VTOC Not supported
Apple Xsan 1.3 
(MacOS X 10.4 
Tiger)
VTOC, EFI VTOC, EFI EFI, sVTOC
Apple Xsan 1.3 
(MacOS X 10.3 
Panther)
a
VTOC, EFI VTOC, EFI EFI, sVTOC