User's Guide
Chapter 6 Troubleshooting
Common Problems and Solutions
92 Quantum P4000 and P7000 Libraries User’s Guide
Start-up Problems 6 Table 18 describes corrective actions for problems which occur during 
start-up.
Table 18 Start-up 
Problems
Problem Corrective Action
The library does not 
power on.
Make sure the power cord is connected to a 
grounded electrical outlet, the power 
distribution assembly (left rear corner of 
cabinet) circuit breaker is on, and the 
power switch behind the slide panel just 
below the GUI is on. 
The library or tape 
drives do not 
respond on the SCSI 
bus.
Make sure each SCSI device on the same 
SCSI bus has a unique address and the last 
device is properly terminated.
During initialization, 
the library reports 
“not ready.”
Determine the failure type by checking any 
previous error codes returned to the host 
computer. Correct the cause of the error.
One or more tape 
drives fail to spin up 
during start-up.
Check all SCSI cabling and termination 
behind the center rear access door. If 
necessary, contact your field service 
representative about replacing the drives.
The library starts up 
in standby mode.
Press the 
Standby button to verify that the 
library switches to on-line mode. You can 
use the GUI to select either on-line or 
standby mode at power up.