User's Guide
Chapter 4 Service Commands
Initializing Non-Volatile Information
Quantum P4000 and P7000 Libraries User’s Guide 83
4 When you have selected the type of test and all test options, press the 
Execute button. 
A “Command In Progress” dialog box is displayed.
The system test continues until completed unless you press the 
Abort 
button. If you pressed the 
Continuous button in step 3, you must 
press the 
Abort button to stop the test.
Initializing Non-Volatile Information 4
The 
Service screen contains two commands involving information stored 
in nonvolatile memory: 
• Initialize nonvolatile memory configuration—returns the library 
configuration to its factory-default condition, eliminating any 
changes made using the Configure Library and Configure Options 
commands in the Operator screen and invalidates the calibration 
data.
• Initialize nonvolatile memory statistics—purges nonvolatile memory of 
all statistical information about library operation. This information is 
used to generate the statistical report described on page 76
.
Executing Either 
Command  4
To execute either command:
1 On the 
Service screen, press the button that corresponds to the 
command you want to execute. The GUI displays a dialog box 
prompting you to Continue or Cancel the command.
Caution: The following two commands are meant to be used only 
by qualified, Quantum-trained personnel. They are 
presented here for explanation only. Serious operational 
problems and data loss may occur if you do not fully 
understand the consequences of these commands.