User's Guide
Chapter 6 Troubleshooting
Common Problems and Solutions
76 Quantum|ATL P3000 Series User’s Guide
Tape Drive 
Problems
6
Table 11
 describes the corrective action for problems with the tape 
drives. 
Table 11 Tape Drive 
Problems
Tape Drive LED 
Conditions
6
These actions are to be performed based on the LED displays on 
the backs of the drive canisters in mixed media P3000 tape 
libraries. Table 12
 and figure 41 show the diagnostic table of tape 
drive conditions as indicated by the two LEDs at the back of the 
tape drive canister.
A maximum 
temperature 
exceeded warning is 
displayed.
Turn off the library and allow it to cool down. Lower the room 
temperature, if possible, and increase ventilation around the library.
(If the operating temperature is too high, the library will automatically 
shut down until the temperature drops.)
Problem Corrective Action
The library is 
unable to 
communicate 
with a drive.
This is indicated by a Drive Communication Time-out error. Contact a 
field service engineer.
The tape drive 
does not eject a 
cartridge.
Reset the library and retry the unload command.
If the tape still does not unload, stop the library, open the front door, and 
manually unload and eject the cartridge (see Manually Ejecting a Tape 
Cartridge on page 40).
A drive handle 
error occurs.
Contact an ATL field service engineer.
Problem Corrective Action