User's Guide
Chapter 5 Multi-Unit Commands
Calibrating the Libraries in a Multi-Unit Configuration
68 Quantum|ATL P3000 Series User’s Guide
Figure 39 Configure 
Multi-Unit
2
Press the Select button to access the option to configure.
3
Using the arrow buttons, scroll through the available values for 
the selected option.
4
When the desired value is displayed, press the Select button to 
advance to the next option.
5
When you have finished making changes to the multi-unit 
configuration options, press the Change button to save the 
options and complete the configuration.
Calibrating the Libraries in a Multi-Unit Configuration
5
The Calibrate All PTMs command enables you to calibrate all pass 
through mechanisms in all of the libraries in the multi-unit 
configuration. Calibrate the libraries during the initial installation 
and after any maintenance procedure.
To calibrate all library elements:
1
From the Master library in the multi-unit configuration, press 
the Multi-Unit tab.
Operator Service
Multi
Unit
Back Forward
Home
O
Configure: Multi-Unit
Change
Select
System
Off-line
Standby
Load Port
Stop
Library Unit:
SINGLE
Library Unit #:
# of Libraries:
LUN Config: SINGLE LUN
About
Quantum|ATL