User's Guide
Chapter 3 Operator Commands
Unloading the Load Port
54 Quantum|ATL P3000 Series User’s Guide
To unload the load port:
1
On the Operator screen, press the Unload Imp/Exp button.
The GUI displays a Command In Progress dialog box is 
displayed.
2
If it becomes necessary to stop the Unload command, press the 
Abort button 
Note:
You can also use the Move Cartridge command to 
unload the load port. The Move Cartridge command is 
especially useful if the destination of the move is 
important. For more information about the Move 
Cartridge command, see Moving Cartridges
 on page 50.”
Note:
The inventory process is also stopped if an error is 
detected. In this case, the GUI displays an error 
message.