User's Guide
Chapter 2 Basic Library Operations
Installing Tape Cartridges
Quantum|ATL P3000 Series User’s Guide 17
• Use an antistatic wrist strap when touching internal library 
components. To use the wrist strap properly, place the band 
around your wrist and attach the clip to the library frame. Keep 
the strap on until you are ready to close the library doors.
• Keep static-sensitive parts in their shipping containers until 
ready for installation.
• Do not place static-sensitive parts on any metal surface. If you 
need to put down a static-sensitive part, place it inside its 
protective shipping bag or on a grounded antistatic mat.
• Avoid direct contact with static-sensitive parts. Avoid touching 
connectors and discrete components.
• Close library door and access panel when not working on the 
library.
• Be very careful when installing the library or handling 
components in dry climates or environments where cold 
weather heating is used. Environments such as these with 
lower relative humidity have greater potential to produce 
static electricity.
DLT/SDLT 
Cartridges
2
The following shows you how to label DLT/SDLT tape cartridges, 
as well as setting the write-protect switch and proper orientation.
Labeling
2
Attaching a bar code label to each tape cartridge enables the library 
to identify the cartridge quickly, thereby speeding up inventory 
time.
Place the label in the slide-in slot on the front of the cartridge (see 
figure 8
).
Note:
In environments with high potential for static 
electricity, you may want to take additional 
precautions such as the use of an antistatic smock or 
a grounded antistatic mat.