User Manual

Product Specification
EVQROCM-01-V03-R0 Installation and Operation Manual Quantum:EV OpenCharge
January 2022 Page 6 of 25
Electrical Specification
Product Code OCPP0410 OCPP0411 OCPP0420 OCPP0421 OCPP0425
C
C
h
h
a
a
r
r
g
g
i
i
n
n
g
g
S
S
o
o
c
c
k
k
e
e
t
t
(
(
s
s
)
)
1x Type 2
(IEC 62196)
2x Type 2
(IEC 62196)
4x Type 2
(IEC 62196)
AC Charging Output
1 x 3.6kW
(16A)
1 x 7.2kW
(32A)
2 x 3.6kW
(16A)
2 x 7.2kW
(32A)
4 x 7.2kW
(32A)
Charge Protocol Mode 3
AC Overload Protection 1x C20A MCB 1x C40A MCB 2x C20A MCBs 2x C40A MCBs 4x C40A MCBs
A
A
C
C
&
&
D
D
C
C
F
F
a
a
u
u
l
l
t
t
P
P
r
r
o
o
t
t
e
e
c
c
t
t
i
i
o
o
n
n
1x Type B RCD 2x Type B RCDs 4x Type B RCDs
Input Supply
1x 16A 230V
AC/50Hz
(Single Phase)
1x 32A 230V
AC/50Hz
(Single Phase)
1x 32A 230V
AC/50Hz
(Single Phase)
1x 63A 230V
AC/50Hz
(Single Phase)
2x 63A 230V
AC/50Hz
(Single Phase)
Cable Terminals 3x 50 mm (2x) 3x 50 mm*
Communications
GPRS (Recommended signal strength of 14 CSQ or better), or
RJ45 ethernet connection
2x RJ45
ethernet
connections
Operating Temperature -30°C to +50°C
*Alternative cable terminal options available upon request
Product Code OCPP0412 OCPP0410 OCPP0422 OCPP0423
C
C
h
h
a
a
r
r
g
g
i
i
n
n
g
g
S
S
o
o
c
c
k
k
e
e
t
t
(
(
s
s
)
)
1x Type 2 (IEC 62196) 2x Type 2 (IEC 62196)
AC Charging Output
1 x 11kW
(16A)
1 x 22kW
(32A)
2 x 11kW
(16A)
2 x 22kW
(32A)
Charge Protocol Mode 3
AC Overload Protection 1x C20A MCB 1x C40A MCB 2x C20A MCBs 2x C40A MCBs
AC & DC Fault Protection 1x Type B RCD 2x Type B RCDs
Input Supply
1x 16A 400VAC
50Hz (3 Phase)
1x 32A 400VAC
50Hz (3 Phase)
1x 32A 400VAC
50Hz (3 Phase)
1x 63A 400VAC
50Hz (3 Phase)
Cable Terminals 5x 50 mm
Communications
GPRS (Recommended signal strength of 14 CSQ or better)
RJ45 ethernet connection
Operating Temperature -30°C to +50°C