User's Guide
  Troubleshooting and Diagnostics  35 
4.  Within 60 seconds, insert a scratch data cartridge that is not write-protected (or the drive will exit Maintenance Mode). 
Caution 
Data on the cartridge will be overwritten. Insert only a scratch data cartridge for 
these tests. 
After you insert the cartridge, the front panel indicators will display the following: 
Indicator  State, Character, or Message 
Status LED 
Amber, solid 
Single-character display 
5 
LCD 
Copy Dump to Tape 
Tape Loading ====  
while the drive writes the dump data to the scratch data tape (at BOT). 
When Copy Dump to Tape finishes copying the data to the scratch cartridge, the front panel indicators display the 
following: 
Indicator  State, Character, or Message 
Status LED 
Amber, solid 
Single-character display 
5 
LCD 
Copy Dump to Tape 
Passed! 
Followed by: 
Cartridge Unloading 
In Progress 
The drive will then unload the cartridge and exit Maintenance Mode. The front panel indicators display the following: 
Indicator  State, Character, or Message 
Status LED 
Green, solid 
Single-character display  Off 
LCD 
Ultrium Tape Drive 
Drive Empty 
If an error occurs while the drive is running the Copy Dump to Tape function, the front panel indicators display the 
following: 
Indicator  State, Character, or Message 
Status LED 
Off 
Single-character display 
7, flashing 
LCD 
Error! 
Media Problem 
To resolve the error, refer to Table 4-2 Error Codes elsewhere in this chapter. To clear the error, cycle (remove, then reapply) 
power to the LTO standalone. 