User's Guide
Quantum|ATL PowerStor L500 Series Tape Library User’s Guide 91
A7H Retry 
command
Timed-out while opening the drives 
handle during a LOAD CARTRIDGE 
command.
A8H See 
Description
Timed-out moving cartridge from the 
CHM into the drive during a LOAD 
CARTRIDGE command.
If this occurs as the only error, then this 
error can be retried. The drive controller 
must first unload the cartridge from the 
drive. Then it can reissue the command.
If this error occurs as the second error 
after either a 94H or an A9H error, then 
this error is considered fatal.
A9H Retry 
command
Timed-out while attempting to find 
PUSHPOS 2 to push cartridge 
completely into the drive during a 
LOAD CARTRIDGE command.
AAH This code is not an error and will never 
be returned in the status error bytes. It is 
utilized in the error trace buffer as an 
indicator every time a thousand cycles 
has occurred.
ABH See 
Description
Timed-out finding PUSHPOS 1 (rack 
waiting position in front of the drive).
This error can be retried. The library 
controller must first unload the cartridge 
from the drive then, reissue the 
command.
ACH Retry 
command
Timed-out closing drive handle. This 
error can occur during a LOAD 
CARTRIDGE command or after error 94 
if the loader controller tries to move the 
cartridge back into the drive.
Error Code Error Type Description