User's Guide

FastStor 2 User’s Guide 51
Table 10 Aborted Command Error Codes
Error Code Details and Description
70H SCSI message error.
71H SCSI parity error.
72H SCSI invalid message.
73H SCSI overlapped command attempt.
74H-79H Reserved.
Table 11 Additional Error Codes
Error Code Details and Description
7AH-7DH Reserved.
7EH Reservation conflict status.
7FH Reserved.
Table 12 Robotic Control Error Control
Error Code Description Details
81H Invalid command error This error indicates that the robotics have received an invalid
command issued by the library controller. A communication
failure or non-matching autoloader code.
82H Device status not
suitable to execute this
command
If the robotics are busy, some commands cannot be executed
at the same time. This error indicates a probable violation.
This is not an error condition, but does result in busy being
reported to the host system for the requested SCSI command.
83H Inventory not valid The cartridge inventory is not valid because of manual
changes or previous fatal errors. Update the inventory using
appropriate Set Slot Status commands.
84H Source element not
ready
The transport source element is empty.
85H Destination element not
ready
The destination element is full.
86H User has attempted to
access the door while
media removal is
prevented
Finish importing or exporting a cartridge. Then retry the
operation.
87H A robotic command has
timed out
Use the Configuration/Reset command to reset the unit.
88H Communications error
during loop-back
Cycle power on the autoloader and attempt the operation
again. If the error recurs, contact your service representative
(refer to Getting Help