User's Guide

44 Troubleshooting and Diagnostics
Expired cleaning cartridge Verify the number of cleanings per cleaning tape for your
media type (see Specifications
on page 59).
Bad/defective/contaminated
media
If the Media Attention LED is cleared and the drive has
been cleaned, and then immediately reappears each time
a particular cartridge is reloaded, that cartridge should be
suspected as being defective, if it is not an invalid cleaning
cartridge.
If this occurs, export the cartridge and load a
known good cartridge. In some cases, a
cartridge can be worn out, have a defective
cartridge memory, or have been formatted as a
Firmware Upgrade Tape.
Any cartridge that is suspected of being
defective or contaminated should NOT be
reused in any drive.
Errors Displayed on Front Panel
“!” in autoloader operator panel
inventory display
See Operating the Autoloader
on page 11 for more
information.
There is an error code on the
LCD display
Look up the error code, try to resolve the failure, and
power cycle (see Viewing Autoloader Error Codes
on
page 47).
Device Not Detected on SCSI Bus
Connected to a high voltage
differential SCSI bus/host
system adapter
Attach device to a LVD SCSI host system adapter/bus.
SCSI cable length exceeded, use shorter cable, or
remove other devices from the bus. Device not properly
terminated (see Installation Issues
on page 39).
Power on device before powering on the host system.
Check that the device has been powered on and is not in
an error state.
SCSI Errors
Connected to a high voltage
differential SCSI bus/host
system adapter
Attach device to a LVD SCSI host system adapter/bus.
SCSI cable length exceeded, use shorter cable, or
remove other devices from the bus (see Installation Issues
on page 39).
Device not properly terminated.
Table 4 Troubleshooting Table
Problem Solution