User's Guide
Chapter 2 Emulated Medium Changer SCSI Commands
Read Element Status (B8h)
66 Quantum DX-Series Software Interface Guide
• Information on the abnormal state is available in the Additional 
Sense Code and Additional Sense Code Qualifier fields in that 
element descriptor. 
Appendix A, Sense Key Values for the 
meaning of the codes contained in the two Sense Code fields
• Import Export
•The Import/Export field is set to 0 if the tape cartridge contained 
in the element was placed there by the transfer mechanism
• It is set to 1 if the tape was placed there by an operator or if its 
source is unknown (e.g., after power cycle)
•Full
•The Full field is set to 1 whenever the element contains a tape 
cartridge 
• It is set to 0 when the element contains no tape or the load port 
door is open
• Additional Sense Code and Additional Sense Code Qualifier
These fields are only valid if the Exception field is set to 1. Currently 
the only valid values for these fields indicate:
• Element Contents Unknown condition (ASC=80 ASCQ=22)
• Cleaning Cartridge Installed (ASC=30 ASCQ=03)
• Operator Medium Removal Request (ASC=5A ASCQ=01)
• SValid
•The SValid bit is set to 1 if the information in the Source Storage 
Element Address field is valid 
• If the information is unknown, the SValid bit is set to 0
•Invert
The Invert field is not supported and is set to 0.
• Source Storage Element Address
The Source Storage Element Address represents the address of the 
last storage element that held the cartridge. The SValid field indicates 
if this information is valid.
The format of an element descriptor for an element of the data transfer 
element type is shown in 
table 46.