User's Guide

Chapter 2 Emulated Medium Changer SCSI Commands
Read Element Status (B8h)
64 Quantum DX-Series Software Interface Guide
These fields are only valid if the Exception field is set to 1. SValid
•The SValid bit is set to 1 if the information in the Source Storage
Element Address field is valid
If information is unknown (due to a door open or power on
condition), the SValid bit is set to 0
•Invert
The Invert field is not supported and is set to 0.
Source Storage Element Address
Source Storage Element Address represents the address of the last
storage element that held the cartridge. The SValid field indicates
whether this information is valid.
Primary Volume Tag Information
If the Volume Tag information is requested in the command block
(VolTag=1), then the Primary Volume Tag Information field is
included in the element descriptor. For format, see
table 43.
The layout of an element descriptor for an element of the import /export
element type is illustrated in
table 45.
Table 45 Import/Export
Element Descriptor
Bit/Byte 7 6 5 4 3 2 1 0
0
(MSB)
Element Address
1
(LSB)
2
Reserved (0)
Import
Enable
Export
Enable
Access Except
Import
Export
Full
3
Reserved (00h)
4
Additional Sense Code
5
Additional Sense Code Qualifier
6
Reserved (000000h)
7
8