User's Guide

Chapter 2 Emulated Medium Changer SCSI Commands
Read Element Status (B8h)
Quantum DX-Series Software Interface Guide 61
Element Address
This field indicates the address of the element being reported by that
element descriptor.
Except
When the element is in a normal state, it is set to 0
When the element is in an abnormal state, it is set to 1
Information on the abnormal state is available in the Additional
Sense Code and Additional Sense Code Qualifier fields
•Full
•The Full field is set to 1 whenever the element contains a tape
cartridge
It is set to 0 otherwise
Additional Sense Code and Additional Sense Code Qualifier
These fields are only valid if the Exception field is set to one.
SValid, Invert, and Source Storage Element Address
This field, and the invert bit information value of 0 indicates these
fields are not valid (
table 44).
Primary Volume Tag Information
If the Volume Tag information was requested in the command block
(VolTag=1), the Primary Volume Tag Information field is included
in the element descriptor. This field contains the information read
from the tape cartridge bar code label; its format is shown in
table 43.
12 - 47
Primary Volume Tag Information
(Field omitted if PVolTag = 0)
48 - 51
Reserved (00000000h)
52
Vendor Unique (0000h)
53
Bit/Byte76543210