User's Guide

Chapter 2 Emulated Medium Changer SCSI Commands
Mode Select (15h)
Quantum DX-Series Software Interface Guide 35
•UInit
Not supported.
•Parity
Not supported.
NBL - No bar code Labels
Valid only if the AInit field value is 1 - when DX-Series system
performs an inventory due to going on-line, and the NBL field
value is 1, bar codes are not scanned and primary volume tags
are set to empty
•If NBL field is set to 0, when the DX-Series system performs an
inventory due to going on-line bar codes are scanned and their
value placed in the corresponding primary volume tag
NRDC - Not Ready Display Control
Not supported.
MDC - Message Display Control
Not supported.
Maximum Parity Retries
Not supported.
Display Message
Not supported.
The format for the Element Address Assignment Page is shown in
table 28.
Table 28 Mode
Select Data - Element
Address Assign. Page
Bit/Byte 7 6 5 4 3 2 1 0
0
PS (0)
Rsrvd
(0)
Page Code (1Dh)
1
Parameter Length (12h)
2
(MSB)
First Medium Transport Element Address
3
(LSB)