User's Guide
Chapter 2 Emulated Medium Changer SCSI Commands
Initialize Element Status with Range (E7h)
14 Quantum DX-Series Software Interface Guide
Initialize Element Status with Range (E7h) 2
The Initialize Element Status with Range command allows the host to 
request an inventory of a range of elements in the DX-Series system. The 
DX-Series system conducts the inventory and determines if each element 
within the range contains a tape cartridge. The inventory reads each 
tape’s bar code (unless commanded not to).
The DX-Series system does not accept any other commands from the host 
during the inventory process.
The host can issue an Abort of the inventory for the DX-Series system. If 
another Initialize Element Status command is then issued, the inventory 
process is restarted from the beginning.
The format for this command data block is shown in table 8.
Table 8 Initialize 
Element Status with 
Range Command
Bit/Byte 7 6 5 4 3 2 1 0
0
1
2
3
4
5
6
7
8
9
• Logical Unit Number
The Logical Unit Number must be set to 0. Field indicates the logical 
unit to which the command is sent.
Operation Code (E7h)
Logical Unit Number Reserved (00h) Range
(MSB)
Starting Element Address
(LSB)
Reserved (00h)
Reserved (00h)
(MSB)
Number of Elements
(LSB)
Reserved (00h)
NBL Reserved (00h)