User's Guide

Appendix E DX-Series Software Deviations
306 Quantum DX-Series Software Interface Guide
Send Diagnostic 5
The DX-Series system does not perform any actual diagnostics indicated
by the command. It will always return a good status for the diagnostics
requested.
See Send Diagnostic (1Dh) on page 100 for more information.
Send Volume Tag 5
The DX-Series system returns a check condition, unsupported command,
whereas the ATL P1000 supports this command.
See Send Volume Tag (B6h) on page 102 for more information.
Test Unit Ready 5
Implemented per specification
See Test Unit Ready (00h) on page 105 for more information.
Write Buffer 5
The DX-Series system returns a check condition, unsupported command,
whereas the ATL P1000 supports this command.
DLT 7000 SCSI
Command
Deviations
5
This section documents where the DX-Series system deviates from a
normal DLT 7000 tape drive.
General Information 5
Tape Cartridge Media Type - All DX-Series tape cartridges are
created of type DLTtape IV.
Tape Cartridge Capacity - The DX-Series tape cartridge capacity will
not necessarily match an actual DLTtape IV. The user is given the
option when creating cartridges to set the capacity depending on his
DX system configuration.