User's Guide
Appendix E DX-Series Software Deviations
302 Quantum DX-Series Software Interface Guide
• DX3000 - 800
• DX5000 - 1600
The ATL P1000 library can be configured with a maximum of 40 
storage elements.
• Data Transport Element - The DX-Series system supports the 
following maximum transport elements:
• DX30 - 30
• DX100 - 55
• DX3000 - 32
• DX5000 - 64
The ATL P1000 library can be configured with a maximum of 4 data 
transport elements. Currently, all DX-Series data transport elements 
are of the Quantum DLT 7000 type, whereas the ATL P1000 supports 
a variety of different tape drive types.
Initialize Element Status 5
Implemented per specification.
See Initialize Element Status (07h) on page 13 for more information.
Initialize Element Status with Range 5
Implemented per specification. This will take less than a second to 
complete whereas a P1000 would take minutes.
See Initialize Element Status with Range (E7h) on page 14 for more 
information.
Inquiry 5
The DX Series supports the additional Pages 80h (Unit Serial Number 
Page) and 83h (Device Identification Page).
See Inquiry (12h) on page 16 for more information.