User's Guide
Appendix C DLT7000 Sense Code Values
Quantum DX-Series Software Interface Guide 291
14 00 Recorded Entity Not Found (logical DLT block
not found)
15 02 Position Error Detected by Read of Medium
1A 00 Parameter List Length Error
20 00 Illegal Opcode
20 81 Illegal Command While In Recovery Mode
21 01 Invalid Element Address
24 00 Invalid CDB Field (may occur if odd block
counts are attempted in fixed mode)
24 81 Invalid Mode on WRITE Buffer
24 82 Media in Drive
24 84 Insufficient Resources
24 86 Invalid Offset
24 87 Invalid Size
24 8C Not Immediate Command
25 00 Illegal LUN
26 00 Parameter List Error, Invalid Field
26 01 Parameter List Error, Parameter Not
Supported
26 02 Parameter List Error, Parameter Value Invalid
27 80 Hardware WRITE Protect
27 82 Data Safety WRITE Protect (if Use Cleaning
Tape LED is lit, use a cleaning tape)
28 00 Not Ready To Ready Transition
ASC ASCQ Description