User's Guide
Appendix B Media Changer Sense Code Values
Quantum DX-Series Software Interface Guide 287
80 22
ELEMENT CONTENTS UNKNOWN
The contents of an element address are 
unknown. Issue a Read Element Status for the 
element address. If contents are still unknown 
issue an Initialize Element Status command.
88 00
WARNING SAFE TEMPERATURE EXCEEDED
This is only a warning that the temperature in 
the DX-Series system exceeds the normal 
operational temperature (96.8
o
F).
88 01
MAXIMUM TEMPERATURE EXCEEDED
DX-Series system turns off and remains off 
until the temperature returns to an acceptable 
level (59-90
o
F).
8F 00
DX-SERIES UNIT COMMAND TIMED OUT
Verify that communications to DX-Series 
system still exists by issuing another command
F0 01
RESERVATION CONFLICT
Internal firmware error. Report this occurrence 
and previous command (if known) to 
Technical Support.
F1 00
COMMAND UNSPECIFIED
Internal firmware error. Report this occurrence 
and previous command (if known) to 
Technical Support.
F1 01
COMMAND HEAP OVERFLOW
Internal firmware error. Report this occurrence 
and previous command (if known) to 
Technical Support.
ASC ASCQ Message Name/Description