User's Guide
Appendix B Media Changer Sense Code Values
286 Quantum DX-Series Software Interface Guide
54 00
SCSI TO HOST SYSTEM INTERFACE FAILURE
Possible SCSI bus time-out or premature 
disconnect. Check cable connections and cable 
length.
80 00
DOOR WAS OPENED INVENTORY MAY HAVE 
BEEN CORRUPTED
Close door and retry command.
80 01
TRANSFER FULL - COMMAND CAN NOT BE 
EXECUTED
Gripper has cartridge in it. Move cartridge to 
empty storage element using 
Move Medium 
command. Retry command.
80 06
TRANSFER EMPTY - COMMAND ABORTED
Gripper does not contain cartridge at end of 
pick portion of 
Move Medium command. 
80 08
LOGICAL UNIT TURNED ON-LINE
The DX-Series system is ready to communicate 
with the host computer.
80 09
LOGICAL UNIT IS TURNED OFF-LINE
The DX-Series system is ready to communicate 
with the diagnostic PC. Set the DX-Series 
system offline from the GUI.
80 0B
COMMAND ABORTED BY USER
Informational message. No action is necessary.
80 0E
DATA TRANSFER CHANGED
A drive has been inserted into the system. Use 
“Read Element Status” to determine status of 
drives. 
80 0F
LOW POWER ERROR
Check power connections.
ASC ASCQ Message Name/Description