User's Guide
Appendix B Media Changer Sense Code Values
286 Quantum DX-Series Software Interface Guide
54 00
SCSI TO HOST SYSTEM INTERFACE FAILURE
Possible SCSI bus time-out or premature
disconnect. Check cable connections and cable
length.
80 00
DOOR WAS OPENED INVENTORY MAY HAVE
BEEN CORRUPTED
Close door and retry command.
80 01
TRANSFER FULL - COMMAND CAN NOT BE
EXECUTED
Gripper has cartridge in it. Move cartridge to
empty storage element using
Move Medium
command. Retry command.
80 06
TRANSFER EMPTY - COMMAND ABORTED
Gripper does not contain cartridge at end of
pick portion of
Move Medium command.
80 08
LOGICAL UNIT TURNED ON-LINE
The DX-Series system is ready to communicate
with the host computer.
80 09
LOGICAL UNIT IS TURNED OFF-LINE
The DX-Series system is ready to communicate
with the diagnostic PC. Set the DX-Series
system offline from the GUI.
80 0B
COMMAND ABORTED BY USER
Informational message. No action is necessary.
80 0E
DATA TRANSFER CHANGED
A drive has been inserted into the system. Use
“Read Element Status” to determine status of
drives.
80 0F
LOW POWER ERROR
Check power connections.
ASC ASCQ Message Name/Description