Table 227 Sense 
Data Values 
(Hexadecimal
ASC ASCQ Message Name/Description
00 00
NO ADDITIONAL SENSE INFORMATION
No recovery necessary.
04 00
LU IS NOT READY, CAUSE NOT REPORTABLE
Check DX-Series system unit power. Retry 
command. 
04 01
LOGICAL UNIT IN PROCESS OF BECOMING 
READY
Wait for DX-Series system unit to complete 
initialization.
04 02
LOGICAL UNIT INIT REQUIRED
Element status or calibration unknown. 
Perform “
Initialize Element Status” command 
(SCSI) or “
Initialize Inventory” command 
(DIAG).
04 03
LU IS NOT READY, MANUAL INTERVENTION 
REQ’D
Initialization failed. Determine failure type by 
checking any previous error code returned to 
host. Correct the cause of the failure and toggle 
STANDBY button.
08 00
LOGICAL UNIT COMMUNICATION FAILURE
Check cables. Ensure DX-Series system unit is 
turned on. Retry command.
08 01 DX-Series system COMMUNICATION TIME-OUT 
ER_LU_COM_TO
QSPI communications not responding. Retry 
command.
1A 00
PARAMETER LIST LENGTH ERROR
Invalid parameter list length field specified by 
command.