User's Guide
Chapter 3 Emulated DLT7000 SCSI Commands
Send Diagnostic (1Dh)
264 Quantum DX-Series Software Interface Guide
Table 213 Sense 
Keys Used for SEND 
DIAGNOSTIC
Additional Sense Codes and Additional Sense Code Qualifiers that apply 
to 
SEND DIAGNOSTIC self-test results are described in the table below.
Table 214 ASC / 
ASCQ for SEND 
DIAGNOSTIC
Sense Key Description
3h Medium Error. A positioning error has occurred in 
which the returned position does not match the 
expected position. Additional Sense Code for 
possible additional information.
4h Hardware Error. The Additional Sense Code and 
any Additional Sense Code Qualifier provide more 
specific information.
5h
ILLEGAL REQUEST. Illegal bit settings in the SEND 
DIAGOSTIC
 command. 
Eh Miscompare. A compare error occurred during a 
READ operation.
ASC ASCQ Description
15h 2h A positioning error has occurred in which the 
returned position does not match the expected 
position.
40h 80h Level 1 ROM Test Failed.
40h 81h Level 1 RAM Test Failed.
40h 82h Level 1 Test Failed. Bad Drive Status.
40h 83h Level 1 Test Failed. Loader Reset Failed.