User's Guide
Chapter 3 Emulated DLT7000 SCSI Commands
Send Diagnostic (1Dh)
258 Quantum DX-Series Software Interface Guide
Send Diagnostic (1Dh) 3
The SEND DIAGNOSTIC command directs the tape drive to perform its 
self-diagnostic tests.
Table 208 SEND 
DIAGNOSTIC 
Command Descriptor 
Block - Data Format
Bit/Byte 7 6 5 4 3 2 1 0
0
1
2
3-4
5
Table 209 SEND 
DIAGNOSTIC 
Command Data - Field 
Descriptions
Operation Code (1Dh)
Logical Unit Number PF (0) Rsv’d Selftst DevOfl UnitOfl
Reserved
 MSB
Parameter list
 LSB 
Unused Reserved
Flag (0) Link (0)
Field Name Description
PF Page Format. Not supported; must be 0.
Selftst Self Test. This bit is used in conjunction with 
DevOfl and UnitOfl to specify the type of testing to 
be done. An explanation is provided in the 
following paragraphs.
DevOfl Device Offline. This bit is used in conjunction with 
Selftst and UnitOfl to specify the type of testing to 
be done. An explanation is provided in the 
following paragraphs.
UnitOfl Unit Offline. This bit is used in conjunction with 
Selftst and DevOfl to specify the type of testing to 
be done. An explanation is provided in the 
following paragraphs.