User's Guide
Chapter 3 Emulated DLT7000 SCSI Commands
Mode Select (6 /10) (15h / 55h)
Quantum DX-Series Software Interface Guide 187
RLEC Report Log Exception Condition. When set to 1,
specifies that the target will report log exception
conditions. When 0, specifies that the target will not
report log exception conditions.
The RLEC bit works in conjunction with the READ
/ WRITE Error Log Sense Page, specifically, the
TMC bit of the READ / WRITE Error Log SENSE
Page (Page 2 and 3), described earlier in this
manual.
The RLEC bit indicates whether the drive should
return CHECK CONDITION status with sense key
set to UNIT ATTENTION when one of the READ
and WRITE error counters of the log pages reach a
specified threshold. Thresholds can be modified
using LOG SELECT.
Queue
Algorithm
Modifier
Must be 0.
Qerr Queue Error. Must be 0.
DQue Disable Queuing. Must be 0.
EECA Enable Extended Contingent Allegiance. Not
supported; must be 0.
RAENP Ready Asynchronous Event Notification. Not
supported; must be 0.
UAAENP Unit Attention Asynchronous Event Notification.
Not supported; must be 0.
EAENP Enable AEN Permission. Asynchronous event
notification is not supported; must be 0.
Ready AEN
Hold off
Period
Not supported; must be 0.
Field Name Description