User's Guide
Chapter 3 Emulated DLT7000 SCSI Commands
Log Select (4Ch)
Quantum DX-Series Software Interface Guide 153
If multiple pages are sent during the DATA OUT phase, they must be 
sent in ascending order according to page code. Otherwise, the command 
terminates with a CHECK CONDITION status, sense key set to ILLEGAL 
REQUEST, and additional sense code set to INVALID FIELD IN 
PARAMETER LIST. The same status is returned if an unsupported Page 
Code appears in any header or if the specified page cannot be cleared.
Log Select Page 
Format
3
Each log page begins with a 4-byte header followed by n number of log 
parameter blocks (one block for each parameter code). Each block, except 
for parameter code 05h is comprised of 8 bytes. The parameter block for 
code 05h is 12 bytes.
Table 105 LOG 
SELECT Log Page 
Header Format
Bit/Byte 7 6 5 4 3 2 1 0
0
1
2-3
Table 106 LOG 
SELECT Log Page 
Header Field 
Descriptions
Reserved Page Code
Reserved
 (MSB)
Page Length
(LSB)
Field Name Description
Page Code The Page Code specifies for which Log Page this 
LOG SELECT command is directed.
Page Length The Page Length field specifies the total number 
of bytes contained in this log page, not including 
the four bytes that make up the header.