User's Guide
Chapter 3 Emulated DLT7000 SCSI Commands
Log Select (4Ch)
Quantum DX-Series Software Interface Guide 151
PC Page Control. This field defines the type of 
parameter values to be selected:
PC Type of Parameter Values
00b - Current Threshold Values
01b - Current Cumulative Values
10b - Default Threshold Values
11b - Default Cumulative Values
All of these types of values are changeable using 
LOG SELECT. 
When the PC field is set to 00b or 01b and the 
Parameter List Length is set to 0, the command 
terminates with a CHECK CONDITION status, 
Sense Key of ILLEGAL REQUEST, and ASC of 
INVALID FIELD IN CDB. This occurs because 
modification of Current Threshold Values and 
Current Cumulative Values is not supported.
When the PC field is set to 10b and the Parameter 
List Length field is set to 10b, then all Current 
Threshold Values are reset to the Default 
Threshold Values. This is equivalent to no 
change, since Threshold Values cannot be 
modified.
When the PC field is set to 11b and the Parameter 
List Length field is set to 0, then all Current 
Cumulative Values are reset to the Default 
Cumulative Values. This is equivalent to clearing 
all log pages that can be cleared.