User's Guide
Chapter 3 Emulated DLT7000 SCSI Commands
Inquiry (12h)
Quantum DX-Series Software Interface Guide 125
Table 79 INQUIRY 
Command Descriptor 
Block - Field 
Descriptions
Field Description
EVPD Enable Vital Product Data. If 0, the drive returns the 
Standard Inquiry Data page. If 1, the drive returns the 
Vital Product Data page specified in Page Code.
Page Code Specifies which Vital Product Data page is to be 
returned by the drive. This field must be 0 if EVPD is 
0. A 
CHECK CONDITION with ILLEGAL REQUEST 
status is returned if this field specifies an unsupported 
page code. Table 80
 lists the page codes for the Vital 
Product Pages supported by the drive.
Allocation 
Length
Specifies the number of bytes of inquiry information 
the drive is allowed to return to the initiator during 
the command's DATA IN phase. Error status is not 
returned if the value in this field truncates the 
requested information.
Flag Bit The Flag bit is used in conjunction with the Link bit to 
notify the initiator in an expedient manner that a 
command has been completed.
Flag bits are not supported by the DX-Series system.
Link Bit A Link bit set to 1 indicates that the initiator requests 
continuation of a task (an I/O process) across two or 
more SCSI commands. 
If the Link bit is 1 and the Flag bit is 0, and the task 
completes successfully, the drive continues the task 
and returns a status of 
INTERMEDIATE and a LINKED 
COMMAND COMPLETE message.
If the Link bit and the Flag bit within a Control word 
are both set to 1, and the drive completes a command 
with a status of 
INTERMEDIATE, the drive returns a 
LINKED COMMAND COMPLETE message (with Flag).
Link bits are not supported by the DX-Series system.