DLT4000/DLT4500/DLT4700 Cartridge Tape Subsystem A-23
A.9.5 Radiated Susceptibility
Table A-25 lists the radiated susceptibility limits:
Table A-25 High Frequency, Electric Fields, 1 to 1000 MHz
3 V/m (rms) 80% modulated 1 KHz No errors, no screen distortion
S/W recoverable errors
No hardware failure
A.9.6 Conducted Susceptibility
The transient voltage is the actual peak voltage above the normal ac voltage from the
power source.
Table A-26 lists the voltage limits for power and data cables:
Table A-26 Fast Transient (Bursts) for Power and Data Cables
2 kV S/W recoverable errors
No hardware failures
Table A-27 lists power cable voltage limits:
Table A-27 High Energy Transient Voltage for Power Cables
1.2 kV No errors
2.5 kV S/W recoverable errors
No hardware failure
_________________________ NOTE ____________________________
Maximum energy in a single pulse from the transient generator must
be limited to 2.5 W.
___________________________________________________________