A.7 Environmental Specifications
Section A.7 describes environmental specifications including:
Topic Section
Temperature and Humidity A.7.1
Altitude A.7.2
The tape drive conforms to an environment that includes general offices and
workspaces with:
Conditioned and marginally-conditioned areas with central or
remote air-conditioning
Complete temperature and humidity controls
Moderate control tolerances
Systems capable of maintaining comfort levels (for example,
typical offices and general work areas)
Marginal heating or cooling apparatus
No humidity conditioning
Uncontrolled tolerances
Systems inadequate to maintain constant comfort levels (for
example, marginal offices and work spaces)
A.7.1 Temperature and Humidity
Table A-8 lists the operating temperature and humidity ranges.
Table A-8 Operating Ranges
Dry Bulb Temperature Range 10 to 40°C
Wet Bulb Temperature 25°C
Temperature Gradient 11°C/h (across the range)
Temperature Shock 10°C (over two minutes)
Relative Humidity 20 to 80% noncondensing
Humidity Gradient 10%/h