User's Manual

Technical Specifications
DLT4000/DLT4500/DLT4700 Cartridge Tape Subsystem A-5
A.2.3 DLT4700 Mini-library Physical specifications
Table A-3 lists the key physical specifications for the DLT4700 mini-library.
Table A-3 DLT4700 Mini-Library Physical Specifications
Description Rack Mount Table Top
Height 26.47 cm (10.42 in) 27.25 cm (10.73 in)
Width 22.20 cm (8.74 in) 22.54 cm (8.875 in)
Length* 68.5 cm (27.0 in) 68.5 cm (27.0 in)
Weight 24.95 kg (55 lb) 29.54 kg (65 lb)
Environmental
temperature
Operating
10°C to 40°C (50°F to 104°F) 10°C to 40°C (50°F to 104°F)
Nonoperating
-40°C to 66°C (-40°F to 150.8°F) -40°C to 66°C (-40°F to 150.8°F)
Humidity
Operating 20% to 80% noncondensing 20% to 80% noncondensing
Nonoperating 10% to 95% 10% to 95%
Certifications
EMI Meets CEmark Class A, VCCi
Class 1, CISPR 22 Class A, FCC
Class A devices
Meets CEmark Class A, VCCi
Class 1, CISPR 22 Class A, FCC
Class A devices
Safety Meets UL, CSA, TUV, "BG"
MARK and IEC standards
Meets UL, CSA, TUV, "BG"
MARK and IEC standards
Maximum number
of cartridges
7 7
Electrical rating 100 to 120/220 to 240 V ac, 2/1 A
Voltage Selection Switch
100 to 120/220 to 240 V ac, 2/1
A Voltage Selection Switch
AC power
requirements
82 W, typical
113 W, maximum
82 W, typical
113 W, maximum
Communication
interface
SCSI-2 bus 8 bits (single-ended or
differential),SCSI-2
bus
SCSI-2 bus 8 bits (single-ended
or differential),SCSI-2
bus
Cycle time 50 s, maximum 50 s, maximum
*Cable length not included.