User's Manual

DLT4000 SCSI Interface
8-66 DLT4000/DLT4500/DLT4700 Cartridge Tape Subsystem
Table 8-4 EEROM Vendor Unique Page Parameters (cont’d)
Name Value Rep. Default Skip
Default
1
Usage
NODISCONFXDBLK ASCII Binary 1 0
To turn on/off feature of not to
disconnect on every fixed block data
transfer.
PROTECTDIRONWP ASCII Binary 0 0
To protect tape directory if the
cartridge write-protect switch is in
write protect position.
ENACLNGLTRPT ASCII Binary 1 0
To report error status if cleaning
light is on.
LONGXPORTPAGE ASCII Binary 1 0
To report 18 or 6 bytes medium
transport element status descriptor if
parameter is on or off.
FORCEEEREBUILD ASCII Binary 0 0
To force all the EEROM parameters
reset to default, if set
SCSIINQVS ASCII Binary 0 0
To return vendor unique inquiry
string, if set
DEFSEW ASCII Binary 1 0
To set default SEW parameter
ENAINITSYNCNEG ASCII Binary 0 0
To enable target initiated
synchronous negotiation, if set.
REPORTRCVDPERRS ASCII Binary 1 0
To report recovered error if parity error has
been retried successfully, if set.
ENATHIRDPTYDENS ASCII Binary 1 0
To make non-DLT density code act as the
default density (same as density code 0), if
set.
FORCEREADSILI ASCII Binary 0 0
To make variable Read command handled as
if the SILI bit is set, if set.
CACHETMS ASCII Decimal 0 0
0,1=Don't cache filemarks unless Imm bit is
1;
2=Cache if not 2 in a row unless Imm bit is
1;
3=Always cache filemarks
LDRCYCLERESET ASCII Binary 0 0
To cause the first cartridge to be loaded if
unloading the last cartridge when the loader
product is operated in sequential mode ,if set.
ENAREPDECOMP ASCII Binary 0 0
If set and the drive is on Read mode, the
decompression algorithm field in Data
Compression mode page will be set if the last
block requested by the host was
decompressed, otherwise it is cleared.
SCSIRESRELNOP ASCII Binary 0 0
SCSI Reserve/Release Unit commands are
NOP, if set.