User's Manual
Technical Specifications
A-20 DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem
Table A-20 list the conducted emission limits.
Table A-20 Conducted Emissions
Frequency Range (MHz) Limits dB
Quasi-peak Average
0.15 to 0.050 66 to 56* 56 to 46
0.50 to 5 56 46
5 to 30 60 50
*The limit decreases with the logarithm of the frequency.
A.6.3 Radiated Emissions
Limits of radiated interference field strength, in the frequency range from 30 MHz to 30
GHz at a test distance of 3 and 10 meters, for Class B equipment are listed in table A-
21.
Table A-21 Radiated Emissions, 30 Mhz to 30 Ghz
Frequency range (MHz) Quasi-peak limit dB (µV/m)
@ 10 m @ 3 m
30 to 230 30 40
230 to 1000 37 46
Above 1000 N/A 54
A.6.4 Magnetic Radiated Susceptibility
Table A-22 lists the magnetic radiated susceptibility limits.
Table A-22 Low Frequency, Magnetic Fields, 10 to 3000 kHz
100 dB (pt) @ 10 kHz declining to
80 dB (pt) @ 1 MHz
No errors, no screen distortion