User's Manual

Technical Specifications
DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem A-13
The tape drive conforms to a modified Class B environment that includes general
offices and workspaces with:
Conditioned and marginally-conditioned areas with central or
remote air-conditioning
Complete temperature and humidity controls
Moderate control tolerances
Systems capable of maintaining comfort levels (for example, typical
offices and general work areas)
Marginal heating or cooling apparatus
No humidity conditioning
Uncontrolled tolerances
Systems inadequate to maintain constant comfort levels (for
example, marginal offices and work spaces)
A.4.1 Temperature and Humidity
Table A-8 lists the operating temperature and humidity ranges.
Table A-8 Operating Ranges
Temperature Range 10 to 40°C
Temperature Gradient 11°C/h (across the range)
Temperature Shock 10°C (over two min)
Relative Humidity 20 to 80% noncondensing
Humidity Gradient 10%/h
Table A-9 lists the power-on ranges.
Table A-9 Power-on Ranges—No Tape Loaded (Unpacked - 72 hours)
Dry bulb temperature 10 to 40°C
Temperature gradient 15°C/h (across the range)
Temperature shock 15°C (over two min)
Relative humidity 10 to 90%
Humidity gradient 10%/h