User's Manual

Technical Specifications
A-4 DLT2000/DLT2500/DLT2700 Cartridge Tape Subsystem
A.2.1 Identifying the Correct AC Power Cord
________________________ Warning ______________________
Do not attempt to modify or use an external 100 - 115 VAC power cord
for 220 - 240 VAC input power. Modifying the power cord can cause
personal injury and severe equipment damage.
_______________________________________________________
An AC power cord was supplied with your unit. Carefully inspect it and make sure that
it is the correct one for your country or region based on the criteria listed below. If you
feel the supplied AC power cord is not correct, contact your authorized Quantum
service representative.
The AC power cord used with this equipment must meet the following criteria:
1. UL and CSA Certified cordage rated for use at 250 VAC with a current rating that
is at least 125% of the current rating of the product. In Europe, the cordage must
have the <HAR> mark.
2. The AC plug must be terminated in a grounding-type male plug designed for use in
your country. It must also have marks showing certification by an agency
acceptable in the country.
3. The connector at the product end must be an IEC type CEE-22 female connector.
4. The cord must be no longer than 14.5 feet (4.5 meters).
__________________________ Note ________________________
The power cord should be a minimum of 18/3 AWG, 60ยบC, Type SJT
or SVT.
_______________________________________________________