User's Manual
DLT2000 SCSI Interface
8-88 DLT2000/DLT2700 Cartridge Tape Subsystem
8.4.10.9 EEROM Vendor Unique Page (3Eh)
The drive supports the EEROM vendor unique page (3Eh). All the EEROM parameters
that are settable through MODE SELECT EEROM vendor unique page are returned.
__________________________Note _____________________________
Because of the long list of parameters, use MODE SENSE (10) instead of
MODE SENSE (6) to retrieve EEROM parameters
____________________________________________________________
Because of the length of the EEROM parameter, a 10-byte MODE SENSE command is
required to retrieve the parameters. If a 6-byte MODE SENSE command is used to
retrieve the EEROM parameter page, the data returned is as follows:
"Send a 10-byte MODE SENSE command to get the Parameter List."
The data returned by the 10-byte MODE SENSE command for the EEROM page is in
the form of a MODE SENSE (10) data header followed by block and page descriptors.
The data in the page descriptor is organized in the form of a parameter header followed
by the actual parameters value. The parameter header is as follows:
"Name T
--------
Current
--------
Default
--------
Minimum
-----------
Maximum
-----------"
Name refers to the parameter name, for example, PRODUCTID or
DEFFAULTCOMPON.
T designates data type: 'b' specifies binary type, 'A' specifies string type, and it is
decimal data type if not specified.
Current/Default/ Minimum/Maximum specifies the current/default/minimum/maximum
value of the parameter.