User's Manual

DLT2000 SCSI Interface
8-66 DLT2000/DLT2700 Cartridge Tape Subsystem
Table 8-3 EEROM Vendor Unique Page Parameters (cont’d)
Name
Value Rep.
Defaul
t
Skip
Default
Length
(Bytes)
Usage
REPORTRCVDPERRS ASCII Binary 1 0 1 To report recovered error if
parity error has been
retried successfully, if set.
ENATHIRDPTYDENS ASCII Binary 1 0 1 To make non-DLT density
code act as the default
density (same as density
code 0), if set.
FORCEREADSILI ASCII Binary 0 0 1 To make variable Read
command handled as if the
SILI bit is set, if set.
CACHETMS ASCII
Decimal
0 0 1 0,1=Don't cache filemarks
unless Imm bit is 1;
2=Cache if not 2 in a row
unless Imm bit is 1;
3=Always cache filemarks
LDRCYCLERESET ASCII Binary 0 0 1 To cause the first cartridge
to be loaded if unloading
the last cartridge when the
loader product is operated
in sequential mode ,if set.
ENAREPDECOMP ASCII Binary 0 0 1 If set and the drive is in
Read mode, the
decompression algorithm
field in Data Compression
mode page will be set if the
last block requested by the
host was decompressed,
otherwise it is cleared.