User's Manual

DLT2000 SCSI Interface
DLT2000/DLT2700 Cartridge Tape Subsystem 8-65
Table 8-3 EEROM Vendor Unique Page Parameters (cont’d)
Name
Value Rep.
Default
Skip
Default
1
Length
(Bytes)
Usage
DISLDRAUTOLDMC ASCII Binary 1 0 1 To partially disable sequential
loading with loader if any media
loader command has been
received.
ENAPARERRRETRY ASCII Binary 0 0 1 To turn on/off parity error etry
feature.
ENAMODEPG22 ASCII Binary 0 0 1 To enable vendor unique Data
Compression (Status Mode
Page).
NODISCONFXDBLK ASCII Binary 1 0 1 To turn on/off feature of not to
disconnect on every fixed block
data transfer.
FOURLAMPMODEL ASCII Binary 0 1 1 If turned on, front panel
SELECT button can only select
2.6 GB, 10.0 GB, or
Compress (done with 10.0 GB
only)
PROTECTDIRONWP ASCII Binary 0 0 1 To protect tape directory if the
cartridge write-protect switch is
in write protect position.
ENACLNGLTRPT ASCII Binary 1 0 1 To report error status if cleaning
light is on.
LONGXPORTPAGE ASCII Binary 1 0 1 To report 18 or 6 bytes medium
transport element status
descriptor if parameter is on or
off.
FORCEEEREBUILD ASCII Binary 0 0 1 To force all the EEROM
parameters reset to default, if set
SCSIINQVS ASCII Binary 0 0 1 To return vendor unique inquiry
string, if set
DEFSEW ASCII Binary 1 0 1 To set default SEW parameter
ENAINITSYNCNEG ASCII Binary 0 0 1 To enable target initiated
synchronous negotiation, if set.