Table 8-3 EEROM Vendor Unique Page Parameters
Name
Value Rep.
Default
Skip
Default
1
Length
(Bytes)
Usage
VENDORID ASCII DEC 1 8 Vendor Identification field in
Inquiry Data
PRODUCTID ASCII DLT2000 1 16 Product Identification field in
Inquiry Data
FORCEDENSITY ASCII
Decimal
0 0 1
0=automatic
2
, 1=DLT260,
2=DLT600, 3=DLT2000
FORCECOMP ASCII Binary 0 0 1 0=automatic
2
, 1=Always
compress unless front panel
selection disables it
DEFAULTCOMPON ASCII Binary 1 0 1 0=Compression defaulted off
on powerup/reset,
1=Compression defaulted to
on, on powerup/reset
DEFFIXEDBLKLEN ASCII
Decimal
0 0 8 Default fixed block size
ENBINQMEDCHGR ASCII Binary 0 0 1 0=disable media changer bit,
1=enable media changer bit
in byte 6 of inquiry data
LOADERLUN ASCII
Decimal
1 0 1 1-7 = LUN to report media
loader device on
REWINDONRESET ASCII Binary 1 0 1 0=Do not rewind on Bus
Reset or BDR msg (Caution:
May have partial block data
written to the tape, if reset
happens during writing.)
1=Rewind the media to BOT
on reset.
ENALDRAUTOLD ASCII Binary 1 0 1 To turn on/off sequential
loading with loader.
1
Parameter setting, if set, remains after the firmware update.
2
Parameter is not forced to a special format, which is decided by the parameters
selected in MODE SELECT.